SERENIUS 50 SO2 ANALYSER

Products  >  Air Quality Monitoring - Reference Methods  >  Gas Analysers  >  Serious 50 SO2 Analyser

The Serinus 50 Sulphur Dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL <0.3ppb, Range 0-20ppm).

 

The Serinus range of analysers have been designed using Ecotech's experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result, instruments that integrate seamlessly into continuous monitoring networks.

APPROVALS

  • US EPA approval (EQSA–0809–188).

  • EN approval TÜV 936/21221977/B.

  • Australian Standard: AS 3580.4.1-2008.

  • Russian approval: 56054-13.

FEATURES & BENEFITS

  • Guaranteed performance with a two year warranty.

  • Minimises time spent on site performing maintenance through superior remote instrument control, diagnostic viewing and calibration.

  • Comprehensive data logging and remote viewing of over 200 operational parameters.

  • Versatile interfacing through RS232, USB, Bluetooth, analogue and optional TCP/IP.

  • Easier setup through an intuitive menu system with “Quick Menu”, advanced GUI and a new larger keypad with tactile keys.

  • Instant display of operational status using illuminated traffic lights on the front panel.

  • Removable flash memory stores 10 years of data, including up to 12 individual parameters and event logs. Operational parameters can also be transferred to memory for easy retrieval.

  • Latest firmware updates can easily be installed using the USB flash memory drive.

  • Programming, viewing, downloading and emailing of data is made even simpler using Bluetooth connectivity combined with the “Ecotech Serinus Remote” Android App.

  • Enhanced operator safety through the use of 12VDC internal voltages.

  • Reduced cost of spare parts, accessories and consumable items through extensive use of standard components across the Serinus range.

  • Improved rack slide design makes accessing internal components and removing the analyser from a rack cabinet easy.

  • Sample pump versatility—choose either an external sample pump suitable for use by multiple analysers or the optional low power internal pump.

  • AQM system power usage can be reduced due to the instrument’s low power demand and its ability to operate over a wide temperature range.

TECHNICAL SPECIFICATIONS

  • Ranges: Autoranging 0-20ppm (Analogue ranges 0-50 ppb to 0-20 ppm)

  • Concentration display: User selectable mg/m3, μg/ m3, ppm, ppb, ppt

  • Noise: < 0.15 ppb

  • Lower detectable limit: < 0.3 ppb or 0.2% of concentration whichever is greater

  • Linearity: < 1% of full scale

  • Precision: 0.5 ppb

  • Zero drift: 24 hours: < 0.5 ppb 7 days: < 0.5 ppb

  • Span drift: 7 days: < 0.5% of reading

  • Response time: 60 seconds to 95%

  • STP reference: 0°C, 20°C, 25°C at 101.3 kPa

  • Sample flow rate: 725 cc/min

  • Temperature range: 0 - 40°C

  • Power: 100-240 VAC, 50 to 60 Hz (autoranging) 255VA (max startup) 180 VA (nominal)

  • Dimensions (wxhxd): 3.5 RU, 429 x 175 x 638 mm

  • Weight: 18.1kg

Communications

Inputs/Outputs: 25 pin I/O port

  • USB port (digital communication).

  • Bluetooth (digital communication via Android App).

  • TCP/IP Ethernet network connection (optional).

  • RS232 Port 1: Digital communication.

  • RS232 Port 2: Multidrop port.

  • Protocols: Modbus RTU/TCP, Bavarian, EC9800, Advanced.

  • Menu selectable current or voltage output 0-20mA, 4-20 mA, or 0-5 VDC (opt 0-10VDC).

  • Menu selectable offset of 0%, 5% or 10%.

  • Auto-ranging from 0-50 ppb to 0-20ppm (between two user specified full scale values).

  • 3 scaleable analogue inputs, 0-5v, 160μV resolution.

  • 8 logic level digital status inputs/8 open collector digital outputs

Options & Accessories

Data Logging

Removable USB flash memory drive that stores data in the following formats:   

 

  • Instantaneous data from: 1, 3, 5, 10, 30, or 60 minute intervals and 2, 5, 10, 30 seconds.

  • Average data from: 1, 3, 5, 10, 15, 30 minutes, 1, 4, 8, 12, or 24 hours.

  • Data storage of 10 years of 12 parameters, 1 minute data on 8 Gb memory

  • External AC powered pump (capable of operating 3 analysers, excluding NOX).

  • Internal long life, low power maintenance free pump (Max 6 watts).

  • Dual filter (particulate), TCP/IP network port.

  • High pressure zero/span valves.

  • Printed manual—electronic manual supplied with analyser.

  • Internal long life, low power maintenance free pump (max 6 watts)

Asia Pacific Air Quality Group Pte Ltd

Registration No: 201324987E

SINGAPORE | INDONESIA

  • APAQ Group on LinkedIn